BT6308-DO Online Dissolved Oxygen Analyzer

BT6308-DO Online Dissolved Oxygen Analyzer

The Bebur BT6308-DO Online Dissolved Oxygen Analyzer comes in two different types of sensors: membrane dissolved oxygen sensors and optical dissolved oxygen sensors. Users can choose the corresponding sensor based on their application requirements for dissolved oxygen monitoring, meeting the diverse choices of users.

Product Details

BT6308-DO Online Dissolved Oxygen Analyzer

The Bebur BT6308-DO Online Dissolved Oxygen Analyzer comes in two different types of sensors: membrane dissolved oxygen sensors and optical dissolved oxygen sensors. Users can choose the corresponding sensor based on their application requirements for dissolved oxygen monitoring, meeting the diverse choices of users.

BT6308-DO Online Dissolved Oxygen Analyzer

Typical applications

The Bebur BT6308-DO Online Dissolved Oxygen Analyzer can be widely applied in dissolved oxygen monitoring in waterworks, surface water, aquaculture, industrial and other fields.

▪Sewage treatment process

▪Water quality monitoring and control in aquaculture

▪Measurement of oxygen content in drinking water, surface water, etc

▪Monitoring of dissolved oxygen in the production process of food and beverages

Optical dissolved oxygen sensor

Optical dissolved oxygen sensors can provide reliable dissolved oxygen measurement over a long service life without the need to replace the membrane, replenish electrolyte solutions, or clean the anode. Maintaining the sensor is as simple as replacing the optical sensor cap every 1-2 years, and since all calibration data is stored on the cap, no calibration is required. This dissolved oxygen sensor outputs Modbus/RS-485 digital signals, facilitating integration with PLC.

Measurement principle: Fluorescence method

Detection range: 0-20mg/L;0-200% saturation

Resolution:±0.1mg/L:±1%

Response time T90:60 seconds

Measurement interval: >5 seconds

Temperature sensor: NTC10K

Temperature accuracy: 0.5℃

Sample temperature: 0-50℃

Maximum pressure: 5 bar(72.5 PST)

Voltage/Power consumption: 12V/1W

Weight: 450g(Only electrode)

Material: 316SS, titanium alloy

Waterproof rating: IP68

Membrane-based dissolved oxygen sensor

The membrane-based dissolved oxygen sensor measures the oxygen content in water using the electrochemical measurement principle. It features a fast response time, accurate measurement results, and simple calibration, requiring only single-point air calibration. Its large electrolyte storage tank reduces downtime caused by maintenance. This dissolved oxygen sensor directly outputs a 4-20mA analog signal or MODBUS/RS485 digital signal, facilitating integration with PLC.

▪The principle of classic primary cells

▪Easy to install and maintain

▪Multiple measurement ranges are available

▪The large volume of electrolyte makes the sensor more stable over the long term

▪mV output, mA output and RS485 output are flexibly selectable

Measurement principle: Electrochemical method

Detection range: 0.00-20ppm:0-200%

Resolution: 0.01

Electrode material: Noryl

Cathode: Silver

Anode: zinc, lead

Temperature sensor: Customized according to customer requirements

Temperature range: 0-50°C

Cable length: 10 feet

Minimum flow rate: 5cm/s 

Weight: 1.68 pounds

Output: 4~20mA and RS485 Modbus RTU output

Power supply requirement: 12-36V DC