BT6308-CD Online Chlorine Dioxide Analyzer

BT6308-CD Online Chlorine Dioxide Analyzer

The Bebur BT6308-CD Online Chlorine Dioxide Analyzer For Water sensor adopts a membrane that is less affected by chlorine, featuring stable performance, low maintenance and long service life.

Product Details

BT6308-CD Online Chlorine Dioxide Analyzer

The Bebur BT6308-CD Online Chlorine Dioxide Analyzer For Water sensor adopts a membrane that is less affected by chlorine, featuring stable performance, low maintenance and long service life.

Online Chlorine Dioxide Analyzer For Water

Typical applications

▪ Online monitoring of chlorine dioxide concentration applicable to the disinfection and sterilization processes of drinking water, polluted industrial process water and pure water, such as:

▪Precise chlorination control for municipal water quality disinfection and secondary water supply disinfection

▪Chlorination disinfection control of water used in food factories and beverage factories

▪Disinfectant control during the cleaning process of fruits and vegetables

▪Water quality monitoring of medical sewage and other wastewater

Performance characteristics

▪The sensor adopts the diaphragm amperometric principle

▪Stable performance and accurate measurement

▪No reagents or buffers are required

▪It is not affected by cleaning agents in water

▪It is less affected by residual chlorine

▪Maintain it once every six months

▪It is applicable to most fields of drinking water and process water for process control

Working principle

The membrane-type chlorine dioxide sensor is a dual-electrode system of membrane-type amperometric polarography, which eliminates zero drift by increasing the current potential. No reagents or buffers are used, and its calibration method is one-point calibration (no need to calibrate the zero point).

The Bebur Online Chlorine Dioxide Analyzer For Water is suitable for occasions where high reliability and ease of operation are required.

Technical parameters

Sensor

Membrane amperometric polarographic dual-electrode sensor

Sensor model

BWCD10.1

Application

Water treatment

Type

Membrane amperometry

Measurement

Chlorine dioxide

Range

0.005-0.5mg/L; 0.005-2mg/L; 0.05-5mg/L; 0.05-10mg/L; 0.05-20mg/L;0.5-200mg/L

Resolution

0.001 mg/L,0.01 mg/L,0.1 mg/L

Repeatability

<1%

Working temperature

0-50℃

Temperature compensation

Automatic compensation is achieved through an integrated temperature sensor

Work pressure

0-0.5bar

Flow rate

0.5L/min

pH value range

pH1-pH12

Initial polarization time

About 1 hour

Response time

The T90 lasts approximately 60 seconds

Zero-point calibration

No need

Calibration

Calibrate using the DPD method every one week to three months

Membrane cap

It is recommended to replace it every 12 to 18 months

Electrolyte

It is recommended to replace it every 3 to 6 months (depending on the water quality).

Interference

O3、CL2

Installation method

Open circulation pool

Related case presentation

Related industry applications