The Bebur BT6308-Peroxi Online Hydrogen Peroxide Analyzer adopts a membrane sensor. It does not require reagents and buffers. The measurement is stable and the performance is reliable. It can reduce the maintenance amount for customers and lower the usage cost.
The Bebur BT6308-Peroxi Online Hydrogen Peroxide Analyzer adopts a membrane sensor. It does not require reagents and buffers. The measurement is stable and the performance is reliable. It can reduce the maintenance amount for customers and lower the usage cost.

Typical applications
▪The BT6308-Peroxi Online Hydrogen Peroxide Analyzer is applicable to the online monitoring of peracetic acid concentration in the disinfection and sterilization processes of drinking water, sewage, industrial process water and pure water, such as:
▪Dosing control for bottle washing machine
▪CIP Factory application
▪Food cleaning water bleaching system
▪Pharmaceutical factories or the field of pharmaceutical intermediates
Performance characteristics
▪The sensor adopts the diaphragm amperometric principle
▪Stable performance and accurate measurement
▪No chemical reagents are needed
▪It is not affected by the cleaning agents in water
▪No zero-point calibration required
▪It has a relatively long service life
▪Suitable for drinking water, process water and brine
Working principle
The hydrogen peroxide sensor is a diaphragm type dual-electrode system. This electrode can automatically adjust the potential to eliminate zero drift. This design enables water quality testing without the need for additional reagents or buffers, reducing the user's usage cost. During calibration, only high-point calibration is required (zero-point calibration is not necessary). The Online Hydrogen Peroxide Analyzer of Bebur can perform automatic dosing process control. It can control the dosage of H2O2(hydrogen peroxide) by automatically adjusting the flow rate, pump speed or valve position to maintain the concentration of hydrogen peroxide stable at the preset value. Automatic dosing can reduce reagent costs and improve the level of process control.
Technical parameters
Sensor | Diaphragm type amperometric polarographic dual-electrode sensor |
Sensor model | BWWP10 |
Range | 0.5-200mg/L, 5-2000mg/L, 50-20000mg/L, 500-50000mg/L, 500-100000mg/L |
Resolution | 0.1mg/L,1mg/L,10mg/L,100mg/L(It depends on the range of the sensor) |
pH range | pH2-pH11 |
Temperature range | 0 to 45℃ (No ice crystals in the measured water) |
Temperature compensation | It is automatically completed by the integrated temperature sensor |
Pressure range | 0-0.5 bar, no pressure shock or vibration |
The first use of polarization time | Five hours |
Response time | T90 takes about 8 minutes |
Flow velocity requirement | Approximately 0.5 liters per minute |
Material | PVC-U, stainless steel, silicone |
Interference | Chlorine, peracetic acid, ozone, sulfides, phenolic substances >3% |
size | Length: 190mm, diameter: 25mm |
Diaphragm | It is recommended to replace it every 12 to 24 months (depending on the water quality). |
Electrolyte | It is recommended to replace it every 3 to 6 months |