BC350 DPD Residual Chlorine / Total Chlorine Analyzer

BC350 DPD Residual Chlorine / Total Chlorine Analyzer

The BC350 model DPD residual chlorine/total chlorine analyzer of Bebur is a water quality analysis device with a compact design, simple structure, and easy operation. This instrument uses the DPD colorimetric method to measure residual chlorine and total chlorine in water: Reagents are injected into the water sample through a reagent pump to complete the reaction, and then the DPD colorimetric method is used to accurately determine the concentration of the water sample. Users can achieve targeted measurement of residual chlorine or total chlorine by selecting different reagents. In addition, the instrument is equipped with a large-capacity data storage device, which can store over 10 years of test data, facilitating users to analyze the long-term water quality change trend of the water body.

Product Details

Product Overview

The BC350 model DPD residual chlorine/total chlorine analyzer of Bebur is a water quality analysis device with a compact design, simple structure, and easy operation. This instrument uses the DPD colorimetric method to measure residual chlorine and total chlorine in water: Reagents are injected into the water sample through a reagent pump to complete the reaction, and then the DPD colorimetric method is used to accurately determine the concentration of the water sample. Users can achieve targeted measurement of residual chlorine or total chlorine by selecting different reagents. In addition, the instrument is equipped with a large-capacity data storage device, which can store over 10 years of test data, facilitating users to analyze the long-term water quality change trend of the water body.

DPD residual chlorine/total chlorine analyzer

Typical Application

▪ Tap water

▪ Municipal water supply pipeline system

▪ Secondary water supply

▪ Disinfection process

▪ Medical industry water usage

Performance Characteristics

▪ Accurate and reliable, with long-term stable automatic operation

▪ Self-diagnosis, custom alarm function

▪ A wider range of measurement intervals, with the minimum being 150 seconds.

▪ Can store test data for more than 10 years

Technical Specifications

Parameters

Residual Chlorine / Total Chlorine

Measurement principle

DPD method

Measurement range

Residual Chlorine:0-2mg/L,0-5mg/L,0-10mg/L

Total Chlorine:0-2mg/L,0-5mg/L,0-10mg/L

Precision

0 - 5 mg/L: ±5% or ±0.05 mg/L (based on Cl2); 0 - 10 mg/L: ±10% (based on Cl2)

Measurement period

Minimum 150 seconds, adjustable

Minimum detectable limit

0.03 mg/L

Size

450×350×200 mm (17.72×13.78×7.87 inch)

Weight

9 kg

Working temperature

5-45 °C (41-113 °F)

Protection level

IP65

Pressure range

0.2-2 bar

Communication method

RS485 (Modbus RTU),WiFi/4G(Optional accessory)

Simulation output

0/4–20 mA

Resolution:< 100 μA

Maximum load:750 Ω

Digital input

1st digital input (used for activating the analysis/flow switch)

Digital output

2-way relay (Max. 250 VAC / 30 VDC 3A)

Data storage

1,000,000 items (32 GB)

Ordering Guide

Reagent type

Controller

Name

Model number

Capacity

Residual chlorine reagent

BC350

Residual chlorine analysis reagent

WAR-DPD-FC1

500 mL

BC350

Residual chlorine buffer reagent

WAR-DPD-BF1

500 mL

Total Chlorine Reagent

BC350

Total Chlorine Analysis Reagent

WAR-DPD-TC1

500 mL

BC350

Total chlorine buffer reagent

WAR-DPD-TF1

500 mL


Related case presentation