GT-3200H Insertable High Temperature Flammable Gas Detector

GT-3200H Insertable High Temperature Flammable Gas Detector

The Bebur GT-3200H Insertable High Temperature Flammable Gas Detector is mainly applied to the detection of NMP concentration in the drying furnace of the coating machine in lithium battery manufacturing. Detection of organic solvent concentration in printed circuit board drying equipment; Detection of paint solvent concentration in steel plate color-coated drying equipment Detection of organic solvent concentration in tape production drying equipment; Detection of organic solvent concentration in film coating and drying equipment, etc.

Product Details

GT-3200H Insertable High Temperature Flammable Gas Detector product overview

The Bebur GT-3200H Insertable High Temperature Flammable Gas Detector is mainly applied to the detection of NMP concentration in the drying furnace of the coating machine in lithium battery manufacturing. Detection of organic solvent concentration in printed circuit board drying equipment; Detection of paint solvent concentration in steel plate color-coated drying equipment Detection of organic solvent concentration in tape production drying equipment; Detection of organic solvent concentration in film coating and drying equipment, etc.

GT-3200H Insertable High Temperature Flammable Gas Detector

GT-3200H Insertable High Temperature Flammable Gas Detector technical parameters

Model

GT-3200H

Gas for detection

N-Methylpyrrolidone(NMP)

Organic solvent gas

Measuring range

0~100%LEL

Resolution

1% LEL

Temperature during use

Instrument body:-20°C~+60°C

Plug-in sensor:-20°C~+160°C

Instrument body:-20°C~+60°C

Plug-in sensor:-20°C〜+200°C

Concentration display

4-bit LCD digital display

Detection accuracy

≤3% LEL

Detection accuracy

≤60S

Alarm value

Level-1 alarm value:25%LEL;Level-2 alarm value:25%LEL

alarm value can be set

Concentration signal output

4~20mA DC

Fault signal output

0.5mADC

Alarm signal output

Output of 2 alarm dry contacts,Output of 1 fault alarm dry contact

 

Alarm contact status

Level-1 alarm contact:Normally open(default),modifiable

Level-2 alarm contact:Normally open(default),modifiable

Fault alarm contact:Normally open(default),modifiable

Alarm delay time

2s(default),modifiable

Explosion-proof class

Exd IICT3

Protection grade

IP65

Cable specification

1.5〜2.0mm2 RVVP shielded cable

Transmission distance

Max.:1km

Working voltage

24V DC(20~28V)

Power consumption

Approx.3W(max.)

Physical dimension

460 (L)×170 (D)×127 (H) mm

Weight

Approx.2.6kg

Means of installation

Quick chuck mounting

Operating mode

Remote control operation