The Bebur BT8500 Liquid Particle Instrument is a device that uses the principle of light blockage to continuously monitor the size, quantity and changes of particles in liquids for 24 hours online. The instrument is reliable in performance, easy to use, and has multiple particle size detection channels to meet the diverse usage needs of users.
The Bebur BT8500 Liquid Particle Instrument is a device that uses the principle of light blockage to continuously monitor the size, quantity and changes of particles in liquids for 24 hours online. The instrument is reliable in performance, easy to use, and has multiple particle size detection channels to meet the diverse usage needs of users.

▪ Industrial process water monitoring
▪ Parts cleaning
▪ Drinking water treatment
▪ Anti-wear protection for equipment
▪ Electronics industry
▪ Fluid cleanliness monitoring
▪ Membrane filtration monitoring
▪ Liquid-cooled component
▪ Monitoring of water used for medical products
The BT8500 Liquid Particle Instrument uses the principle of light blockage to detect particles in liquids. When particles in the liquid pass through the laser sensor, the sensor calculates the size and quantity of the particles based on the amount of beam loss and the number of breaks.
▪ Measurement principle: Light obscuration method
▪ Sensor type: Laser sensor
▪ Standard 8 particle size detection channels, users can set them by themselves (16 channels, 24 channels, 32 channels are optional)
▪ Measurement range: 1-200 microns, 2-400 microns, 2-750 microns
▪ Particle size reporting range: 2-300 microns (For more particle size reporting ranges, please contact the manufacturer for customization)
▪ Count value report: Number per milliliter, or the total number in each measurement period
▪ External sensor, easy to clean
▪ 7-inch high-resolution color touch screen, setting parameters and displaying measurement results, easy to operate
▪Real-time sensor alarms, fault displays, and prompts for maintenance requirements, etc
▪The instrument is equipped with an internal calibration function, allowing for high-precision on-site calibration without the need for return to the factory, thus saving time and costs
▪MODBUS RTU,RS485,USB, and 4-20mA output options are available to meet various data transmission needs
▪ You can choose either an integrated or split installation
Product Model: BT8500
Sensor models: BSLP200, BSLP400, BSLP750
Measurement principle: Light obscuration method
Measurement channels: Standard 8 particle size detection channels, which users can set by themselves (16 channels, 24 channels, and 32 channels are optional)
Flow rate: 60ml/min (applicable range: 2-400 microns for products) 120ml/min (applicable to products with a measurement range of 2-750 microns) Speed regulation of the overflow weir
Laser source: 5mW output red laser diode
Signal-to-noise ratio: ≥3:1
Measurement precision: 10 microns <8%, 2-10 microns <10%
Case: NEMA 4X
Touch screen: 7-inch high-resolution color touch screen
Exterior dimensions: 12 inches wide x10 inches high x6 inches deep
Input power supply: 100-240V, 50-60Hz, 0.5A
Output power supply: 12VDC, 1.67A
Data output: Standard MODBUS (RTU) -RS485, optional: 4-20mA
Counting mode
Cumulative mode (C): The total number of particles larger than the particle size of a certain measurement channel
Grouping mode (D) : The number of particulate matter between two adjacent measurement channels
Measurement range: 1-200 microns, 2-400 microns, 2-750 microns
Particle size reporting range: 2-300 microns (For more particle size reporting ranges, please contact the manufacturer for customization)
Data storage function: with
Operating environment temperature: 5-50°C (41-122°F
Storage environment temperature: 0-50°C (32-122°F)
Relative humidity: 18-80% (non-condensing)
Weight: 5kg
Installation accessories: Sensor protection filter, sensor injection and discharge hose
Optional: Sensor cleaning kit
Installation methods: Overflow weir installation, flowmeter installation