Why Monitor Peracetic Acid Online?
Peracetic acid (CH₃CO₃H, PAA) is a powerful, residue-friendly disinfectant used across drinking water, food & beverage and pharmaceutical processes. Its concentration must stay within a narrow window: too low and disinfection fails; too high and you face corrosion, off-flavors and residual-chemical risk.
The Bebur BT6308-Pera peracetic acid analyzer provides continuous online PAA measurement and can directly drive automatic dosing control — adjusting flow rate, pump speed or valve position to hold the PAA concentration at its setpoint, cutting reagent consumption and raising process control quality.
Product Overview
BT6308-Pera Peracetic Acid Analyzer at a Glance
- Measuring PrincipleMembrane amperometric dual-electrode
- Measuring Ranges0.05–20 ppm up to 50–50000 ppm
- Resolution0.01 / 0.1 / 1 / 10 ppm (by range)
- pH RangepH 1–6 (BPES7) / pH 1–8 (BP9.3, BP10.1)
- CalibrationSpan only, every 1–3 months
- ReagentsNone required
- Flow RequirementApprox. 0.5 L/min
- Standard SupplyController + sensor + membrane cap + electrolyte + FC01 flow cell
How It Works
The PAA sensor is a membrane-covered dual-electrode system that automatically adjusts its potential to eliminate zero drift. Peracetic acid molecules diffuse through the selective membrane and react electrochemically, generating a current proportional to concentration. Temperature compensation is handled automatically by the integrated temperature sensor.
This design eliminates the need for additional reagents or buffers in water quality measurement, reducing operating costs. Calibration requires only a high-point (span) calibration — no zero calibration.
Key Features
Membrane Amperometric Sensor
Dual-electrode membrane sensor based on the amperometric principle, with automatic potential adjustment against zero drift.
Reagent-Free Operation
No chemical reagents or buffers needed — lower operating cost and less routine maintenance.
No Zero Calibration
Stable baseline design; calibration requires only a single high-point span adjustment every 1–3 months.
Unaffected by Detergents
Measurement is not influenced by cleaning agents present in the water — essential for CIP and bottle-washing lines.
Long Service Life
Membrane caps and electrolyte are replaceable consumables; sensor bodies in PVC-U/PEEK with stainless steel 1.4571.
Wide Media Compatibility
Suitable for drinking water, process water and brine applications across municipal and industrial sites.
Sensor Selection — Three Options
| Parameter | BPES7 | BP9.3 | BP10.1 |
|---|---|---|---|
| Type | Membrane amperometric polarographic dual-electrode sensor | ||
| Ranges | 0.5-200, 5-500, 5-1000, 5-2000, 50-5000, 50-10000 ppm | 0.5-200, 5-2000, 50-20000 ppm | 0.05-20, 0.5-200, 5-2000, 50-5000, 50-20000, 50-50000 ppm |
| Resolution | 0.1 / 1 / 10 ppm | 0.1 / 1 / 10 ppm | 0.01 / 0.1 / 1 / 10 ppm |
| pH Range | pH 1–6 | pH 1–8 | pH 1–8 |
| Temperature Range | 0–45 °C (no ice crystals) | 0–60 °C (no ice crystals) | 0–45 °C (no ice crystals) |
| Temp. Compensation | Automatic, via integrated temperature sensor | ||
| Pressure Range | 0.5 bar, no pressure shocks or vibration | ||
| First Polarization | Approx. 3 hours | 30–180 min | 30–180 min |
| Response Time | T90 approx. 3 min | T90 approx. 3.5 min @10 °C; approx. 45 s @50 °C | T90 approx. 1.5–3.5 min (by type & temperature) |
| Flow Requirement | Approx. 0.5 L/min | ||
| Materials | PVC-U, stainless steel 1.4571 | PEEK, stainless steel 1.4571 | PVC-U, stainless steel 1.4571 |
| Calibration | Recommended every 1–3 months | ||
| Interferences | Chlorine dioxide, hydrogen peroxide, ozone | ||
Standard Supply Scope
| Configuration | Controller | Sensor | Membrane Cap | Electrolyte | Flow Cell |
|---|---|---|---|---|---|
| PAA Analyzer #1 | BT6308 | BPES7 | M7.1N, M7.1L | EPS7/W, EPS7L/W | FC01 |
| PAA Analyzer #2 | BT6308 | BP9.3 | M9.3N (M9.1N/G-H) | EPS9H/W, EPS9L/W | FC01 |
| PAA Analyzer #3 | BT6308 | BP10.1 | M10.1N+G, M10.1G+G | EPS9H/W, EPS9L/W | FC01 |
When ordering, please tell us your application industry and the characteristics of the measured medium so we can provide suitable technical guidance.
Installation Options
The analyzer supports multiple installation styles to match site conditions:
Flow Cell Installation
Open or closed FC01 flow cell for stable 0.5 L/min sample flow
Multi-Channel / Self-Cleaning
Open multi-channel flow cells and self-cleaning device options
Typical Applications
- Bottle washer dosing control — precise PAA dosing on returnable-bottle washing lines
- CIP plants — clean-in-place disinfection concentration monitoring in dairy, beverage and brewing
- Food washing water bleaching systems — PAA residual control in produce washing
- Pharmaceutical & intermediates — disinfection process verification and control
- Drinking water, wastewater & process water — online PAA residual monitoring for disinfection processes
Application Cases
The peracetic acid analyzer is deployed across beverage, dairy, municipal water and pharmaceutical facilities. The cases below show typical installation scenarios.

Bottle Washer Dosing Control
Online PAA monitoring with automatic dosing control keeps disinfectant concentration stable on returnable-bottle washing lines, preventing under-dosing failures and over-dosing residue.

CIP Disinfection Monitoring
Continuous PAA measurement in clean-in-place circulation loops verifies disinfection strength in real time — unaffected by cleaning agents present in the water.

Drinking Water Disinfection
Residual PAA monitoring at municipal water plants and wastewater outlets supports disinfection compliance with reagent-free, low-maintenance operation.

Purified Water & Pharma Processes
PAA concentration verification in purified water and pharmaceutical intermediate processes, with traceable online records from the BT6308 controller.
Frequently Asked Questions
What is the Bebur peracetic acid analyzer used for?
How does the membrane amperometric PAA sensor work?
What sensor models and measuring ranges are available?
Does the analyzer need reagents or zero calibration?
Can the analyzer control PAA dosing automatically?
Related Products
- Streaming Current Detector
- Liquid Particle Counter
- Liquid-Cooled pH Sensor
- Liquid-Cooled Turbidity Sensor
Reagent-Free PAA Monitoring That Stays on Target
With membrane amperometric sensing, span-only calibration and built-in automatic dosing control, the Bebur peracetic acid analyzer keeps disinfection processes compliant while cutting reagent and maintenance costs — from bottle washing lines to pharmaceutical CIP.
Contact the Bebur team with your application and medium details for selection guidance and pricing.